TROLLING BANK VSR OPERATION
The Trolling Bank VSR (TBVSR) allows charging of 24 V
DC trolling motor battery banks from 12 V DC systems. When
the engine is started and the start battery reaches 13.7 V
DC, the TBVSR cuts in, charging Trolling battery (A) for
one minute, then Trolling battery (B) for one minute. This
continues as long as the engine is running and the voltage
is over 12.8 V DC. When the boat has reached the fishing
spot and the engine is switched off the battery voltage
will drop below 12.8 V DC, at this time the TBVSR cuts out
and stays disengaged.
SPECIFICATIONS
Continuous 70 Amps
Intermittent 100 Amps
Ignition Protected UL1107
Engages 13.7 V DC
Disengages 12.8 V DC
dimensions102mm x 102mm x 104H